Plan Analysis of 3 BHK – Bungalow (254 sq.mt.)

Plan Analysis of 3 BHK - Bungalows (254 sq. mt.) - Ground Floor Plan

Here we have analysed and reviewed the design of 3 BHK bungalow admeasuring 254.00 sqm. Good features have been shown as recommended and undesirable features have been shown as “Not Recommended”.
The road on which the house abuts and North have also been shown in the sketch.

Plan Analysis of 3-BHK Bungalows 254 sq.mt

R1 – Position & Orientation of Entrance steps recommended to be changed as per given plan.
R2 – Windows in opposite walls are good for cross ventilation.       
R3 – Cupboard in internal wall is recommended. Cupboard on exterior wall are not desirable as they may get damaged due to moisture / dampness in wall. The plywood will get damaged due to moisture.
R4 – TV at distant from sitting area is better.
R5 – Good sitting arrangement.
R6 – Kitchen, Store room & Wash area are well located and connected.
R7 – The entry to the house divides Living room-Kitchen-Dining and other rooms which is good.
R8 – Good space provided for storage rather than providing a separate small store room.
R9 – Bedroom is in wind direction.
R10 – Concept of dry and wet space is maintain in toilets.
R11 – Good indirect entry to the Bedroom.
R12 – Good sitting arrangement in family sitting.

Plan Analysis of 3-BHK Bungalows 254 sq.mt

NR1 – Such tight space with less depth for Wash Area is not recommended, as it is not comfortable for working.
 NR2 – Toilet on First floor will be above kitchen/Dining. This create two problems :

  • Because of sunken slab of toilet it will reduce height of kitchen.
  • There can always be problem of leakage creating nuisance in kitchen.

NR3 – Cupboard would be better in wall adjacent to toilet as it will not obstruct the movement space and passage leads up to outward balcony.
NR4 – Basin should face North so that counter can be provided.
NR5 – No cross ventilation is provided in this room. Though  possible.
NR6 – Open seating Area in Southwest corner is not recommended as it would be very hot during most of the day time.

  • Provision of solar shading device is recommended or light roof shelter to be provided.

NR7 – No space for T.V. unit in family sitting area.
NR8 – Large passage is a sign of wastage of area.

Also Read:
Analyse the Plan of 3 – BHK Duplex (157 Sq.mt)
Plan Analysis of 3 BHK – Row House (135 Sq.mt)

Recommended

R2.

Windows in opposite walls are good for cross ventilation.

Recommended

R2.

Windows in opposite walls are good for cross ventilation.

Recommended

R3.

Cupboard in internal wall is recommended. Cupboard on exterior wall are not desirable as they may get damaged due to moisture / dampness in wall. The plywood will get damaged due to moisture.

Recommended

R10.

Concept of dry and wet space is maintain in toilets.

Recommended

R10.

Concept of dry and wet space is maintain in toilets.

Recommended

R11.

Good indirect entry to the Bedroom.

Recommended

R8.

Good space provided for storage rather than providing a separate small store room.

Recommended

R6.

Kitchen, Store room & Wash area are well located and connected.

Recommended

R7.

The entry to the house divides Living room-Kitchen-Dining and other rooms which is good.

Recommended

R4.

TV at distant from sitting area is better.

Recommended

R1.

Position & Orientation of Entrance steps recommended to be changed as per given plan.

Recommended

R2.

Windows in opposite walls are good for cross ventilation.

Recommended

R5.

Good sitting arrangement.

Recommended

R2.

Windows in opposite walls are good for cross ventilation.

Non Recommended

NR3.

Cupboard would be better in wall adjacent to toilet as it will not obstruct the movement space and passage leads up to outward balcony.

Non Recommended

NR4.

Basin should face North so that counter can be provided.

Non Recommended

NR4.

Basin should face North so that counter can be provided.

Non Recommended

NR1.

Such tight space with less depth for Wash Area is not recommended, as it is not comfortable for working.

Recommended

R2.

Windows in opposite walls are good for cross ventilation.

Recommended

R10.

Concept of dry and wet space is maintain in toilets.

Recommended

R11.

Good indirect entry to the Bedroom.

Recommended

R12.

Good sitting arrangement in family sitting.

Recommended

R10.

Concept of dry and wet space is maintain in toilets.

Recommended

R2.

 Windows in opposite walls are good for cross ventilation.

Recommended

R9.

Bedroom is in wind direction.

Recommended

R2.

Windows in opposite walls are good for cross ventilation.

Non Recommended

NR3.

Cupboard would be better in wall adjacent to toilet as it will not obstruct the movement space and passage leads up to outward balcony.

Non Recommended

NR6.

Open seating Area in Southwest corner is not recommended as it would be very hot during most of the day time.

  • Provision of solar shading device is recommended or light roof shelter to be provided.

Non Recommended

NR5.

No cross ventilation is provided in this room. Though  possible.

Non Recommended

NR4.

Basin should face North so that counter can be provided.

Non Recommended

NR7.

No space for T.V. unit in family sitting area.

Non Recommended

NR2.

Toilet on First floor will be above kitchen/Dining. This create two problems :

  • Because of sunken slab of toilet it will reduce height of kitchen.
  • There can always be problem of leakage creating nuisance in kitchen.

Non Recommended

NR8.

Large passage is a sign of wastage of area.

Non Recommended

NR4.

Basin should face North so that counter can be provided.