Plan Analysis of 4 BHK – Bungalow (470 sq.mt.)

4 BHK - Bungalows (470 sq. mt.) - Ground Floor Plan


Here we have analysed and reviewed the design of 4 BHK bungalow admeasuring 470.00 sqm. Good features have been shown as recommended and undesirable features have been shown as “Not Recommended”.
The road on which the house abuts and North have also been shown in the sketch.

Plan Analysis of 4 BHK – Bungalow

R1 – Window in opposite walls are good for cross ventilation.
R2 – Good seating arrangement in living room bifurcating formal and informal living!
R3 – This area replicate a vast entrance to your home, with natural skylight from the top! Which same time also replicate a wastage of space!
R4 – Bedroom location is in prevailing wind direction, which is good from a planning point of view!
R5 – The entry to the house divides living room-kitchen-dining and other areas which is good!
R6 – Concept of dry and wet space is maintained in Toilet!  
R7 – Well planned layout for bedrooms.
R8 – Center door in rectangle toilets are very good! If directly separates the dry & wet area.

NR1 – Very less space to go through the passage!
NR2 – Very large store room, which is too much for the bungalow! Instead, you can use this direction for another bedroom for your guest, as it is also in wind direction!
NR3 – Too much wastage of space, it needs to be replaced and store room can be located in this area!
NR4 – No attached toilet and dressing room with bedroom!

Also Read: How to Create a Dressing Room?

NR5 – No separate entry from parking, instead of the window it can be used as a door.
NR6 – Steps planned into the usable area of veranda, it is advised to plan outward!
NR7 – Inadequate distance provided from television to seating, it should be more as per overall bungalow space designed & its utilization!
NR8 – Toilet at end doesn’t seem fruitful, as it is far away from all rooms.  
NR9 – Good indirect light but no cross ventilation in a room.
NR10 – No cross ventilation in this room.
NR11 – Not enough windows provided in living room towards garden side.
NR12 – Not enough space for family seating.
NR13 – Common toilet is too far in a house!

Also Read:

Recommended

R4.

Bedroom location is in prevailing wind direction, which is good from a planning point of view!

Recommended

R1.

Window in opposite walls are good for cross ventilation.

Recommended

R6.

Concept of dry and wet space is maintained in Toilet!

Recommended

R1.

Window in opposite walls are good for cross ventilation.

Recommended

R1.

Window in opposite walls are good for cross ventilation.

Recommended

R2.

Good seating arrangement in living room bifurcating formal and informal living!

Recommended

R5.

The entry to the house divides living room-kitchen-dining and other areas which is good!

Recommended

R3.

This area replicate a vast entrance to your home, with natural skylight from the top! Which same time also replicate a wastage of space!

Non Recommended

NR8.

Toilet at end doesn’t seem fruitful, as it is far away from all rooms.

Non Recommended

NR2.

Very large store room, which is too much for the bungalow! Instead, you can use this direction for another bedroom for your guest, as it is also in wind direction!

Non Recommended

NR13.

Common toilet is too far in a house!

Non Recommended

NR3.

Too much wastage of space, it needs to be replaced and store room can be located in this area!

Non Recommended

NR1.

Very less space to go through the passage!

Non Recommended

NR4.

No attached toilet and dressing room with bedroom!

Non Recommended

NR5.

No separate entry from parking, instead of the window it can be used as a door.

Non Recommended

NR7.

Inadequate distance provided from television to seating, it should be more as per overall bungalow space designed & its utilization!

Non Recommended

NR6.

Steps planned into the usable area of veranda, it is advised to plan outward!

Non Recommended

R11.

Not enough windows provided in living room towards garden side.

Non Recommended

NR14.

Wrong Placement of toilet in front & also above the garden!  

Non Recommended

NR9.

Good indirect light but no cross ventilation in a room.

Non Recommended

NR12.

Not enough space for family seating.

Non Recommended

NR11.

Not enough windows provided in living room towards garden side.

Recommended

R7.

Well planned layout for bedrooms.

Recommended

R6.

Concept of dry and wet space is maintained in Toilet!

Recommended

R7.

Well planned layout for bedrooms.

Recommended

R7.

Well planned layout for bedrooms.

Recommended

R8.

Center door in rectangle toilets are very good! If directly separates the dry & wet area.

Recommended

R8.

Center door in rectangle toilets are very good! If directly separates the dry & wet area.

Recommended

R6.

Concept of dry and wet space is maintained in Toilet!

Recommended

R6.

Concept of dry and wet space is maintained in Toilet!

Need help in planning your home?